- General Details
- Technical Details
- Area Classification
- Performance
- Speed Range
- Misc
- Enclosure: TEFC
- HP: 40
- Pole: 4
- RPM: 1800
- Frame: 324T
- Category: Severe Duty
- KW: 29.84
- Motor Standards: NEMA
- Motor Type: AC Motor
- Phase: 3
- Hertz: 60
- Efficiency: Premium Efficiency
- Enclosure: TEFC
- HP: 40
- Pole: 4
- RPM: 1800
- Frame: 324T
- Full Load Amps: 46.3
- Weight: 740
- Nema Design: B
- Duty: S1
- Insulation Class: Class F
- Ambient Teperature: 40C
- Service Factor: 1.15
- Temperature Rise: Class B
- Ingress Protection: IP55
- Elevation: 3300ft
- Rotor: Die Cast Aluminum
- Frame Material: Cast Iron
- Paint: 2 Part Epoxy
- Nameplate: Stainless Steel
- Nema Standards: NEMA MG1, Part 31.4.4.3.
- Space Heaters: Optional
- KW: 29.84
- Voltage: 460
- Class: I & II
- Division: II
- Full Load Speed: 1770
- Efficiency 100: 93
- Efficiency 75: 94.5
- Efficiency 50: 94.5
- Power Factor 100: 86
- Power Factor 75: 84.5
- Power Factor 50: 78.5
- Locked Rotor Torque: 205
- Breakdown Torque: 220
- Locked Rotor Current: 290
- Rotor Inertia lb ft: 8.624
- CT: 20:01
- VT: 60:01:00
- Voltage: 460
HH0404 Crossovers
Baldor ECP64110TR-4
- Category: Severe Duty
- HP: 40
- Voltage: 460
- Frame: 324T
- Enclosure: TEFC
- Efficiency: Premium Efficient
- Hertz: 60
- RPM: 1800
Teco Westinghouse (Canada) APH0404
- Category: Severe Duty
- HP: 40
- Voltage: 460
- Frame: 324T
- Enclosure: TEFC
- Efficiency: Premium Efficiency
- Hertz: 60
- RPM: 1800