Compare
Clear

Elektrim 60NCS-3-75-18

Card brand motor
Get full specifications on Elektrim 60NCS-3-75-18
  • General Details
  • Technical Details
  • Area Classification
  • Performance
  • Speed Range
  • Misc
  • Enclosure: TEFC
  • HP: 75
  • Pole: 4
  • RPM: 1800
  • Frame: 365TC
  • Category: Severe Duty
  • Motor Standards: NEMA
  • Phase: 3
  • Hertz: 60
  • Efficiency: Premium
  • Enclosure: TEFC
  • HP: 75
  • Pole: 4
  • RPM: 1800
  • Frame: 365TC
  • Full Load Amps: 185.8-168/84
  • Weight: 1012
  • Insulation Class: F
  • Service Factor: 1.2
  • Ingress Protection: 86
  • Frame Material: Cast Iron
  • Paint: RAL5010
  • Voltage: 208/230/460V
  • Full Load Speed: 1787
  • Efficiency 100: 95.4
  • Efficiency 75: 95.8
  • Efficiency 50: 95.5
  • Power Factor 100: 88
  • Power Factor 75: 86
  • Power Factor 50: 80
  • Locked Rotor Torque: 150
  • Breakdown Torque: 210
  • Locked Rotor Current: 645
  • Rotor Inertia lb ft: 17.8
  • CT: 10:1
  • VT: 20:1
  • Voltage: 208/230/460V

Schedule a meeting

Follow the link below to learn more about the system and schedule a meeting with one of our experts

Book now
Industrial worker with binder