Compare
Clear

Brook Crompton BC2N050-5C

Card brand motor
Get full specifications on Brook Crompton BC2N050-5C
  • General Details
  • Technical Details
  • Area Classification
  • Performance
  • Speed Range
  • Misc
  • Enclosure: TEFC
  • HP: 50
  • Pole: 2
  • RPM: 3600
  • Frame: 326TSC
  • Category: Severe Duty
  • KW: 37.3
  • Motor Standards: NEMA
  • Motor Type: AC Motor
  • Phase: 3
  • Hertz: 60
  • Efficiency: Premium Efficiency
  • Enclosure: TEFC
  • HP: 50
  • Pole: 2
  • RPM: 3600
  • Frame: 326TSC
  • Full Load Amps: 45.6
  • Weight: 775
  • Nema Design: B
  • Duty: S1
  • Insulation Class: F
  • Ambient Teperature: -15 to 40 C?
  • Service Factor: 1.25
  • Temperature Rise: Class B
  • Ingress Protection: IP55
  • Elevation: <3300 ft
  • Frame Material: Cast Iron
  • Nema Standards: NEMA MG1-Part 31
  • Flange: C-Flange
  • KW: 37.3
  • Voltage: 575
  • Class: I
  • Division: 2
  • Zone: 2
  • Group 2: IIA & IIB
  • Efficiency 100: 93
  • Efficiency 75: 93
  • Efficiency 50: 92
  • Power Factor 100: 0.88
  • Power Factor 75: 0.87
  • Power Factor 50: 0.82
  • Locked Rotor Torque: 200
  • Breakdown Torque: 280
  • Locked Rotor Current: 288
  • CT: 15:01
  • VT: 20:01
  • Voltage: 575

Schedule a meeting